fire sprinkler pipe color codecharleston section 8 housing list

We can handle projects of any size and as many locations as you have. Warehouse Management Proper warehouse management can dramatically improve both efficiency and safety. *Section BC 903.1.1 was amended by Local Law 195 of 2018. Aug 23, 2012. Jan 4, 2007. Sprinkler Type (Pendent/Upright/Quick response, etc.,) Temperature Rating. Pipe Markers Made to Your Exact Specifications. Color bands used for pipe identification shall be located at frequent intervals on straight pipe runs, close to valves and changes in directions, and where pipes pass through walls and floors. COMPOUND COLOR CODE: GENERAL SERVICE APPLICATION: E (TYPE A)-40°F to +150°F (-40°C to 66°C) Pre-Lubricated Violet: Wet & Dry (oil free air) Pipe in Fire Protection Systems. 907.6.4 – NFPA 13 . 4901 Kesslersville Road Easton, PA 18040. It also helps prevent corrosion of the pipes. Pipe Contents Color Scheme Fire-quenching substances White text on red Toxic and corrosive fluids Black text on orange Flammable or Oxidizing fluids ... (Safety Color Code for Marking Physical Hazards) or 1910.145 (Specifications for Accident Prevention Signs and Tags). Other fire sprinkler or supply pipe exposed to the sky or susceptible to wet conditions shall be painted (any color) or otherwise coated to inhibit corrosion. In 1895, a Committee on Automatic Sprinkler Protection was formed in Massachusetts by men affiliated with several fire insurance companies and a pipe manufacturer to develop a uniform standard for the design and installation of fire sprinkler systems. Pipe labels should show the name of the gas/vacuum system or the chemical symbol. ... How To Read The Nfpa Diamond And Color Bar System Seton Blog 2019 Edition . Maybe there is something on that in the fire code. FPA Australia's Technical Specifications for Automatic Fire Sprinkler Systems Design and Installation for both FPAA101D (Drinking Water Supply) and FPAA101H (Hydrant Water Supply) were first published in December 2018. More about EN10216-1 Seamless steel tube for fire protection. *. Surface: Red painted, Hot dip galvanized, Black painted. DISTRIBUTORS. Codes and Standards - Piping codes and standards - ASME, ANSI, ASTM, AGA, API, AWWA, BS, ISO, DIN and more..; Related Documents . Cables are not to be supported by pipes, but that doesn't seem to be the case in your situation. Our informal interpretation is that using the fire sprinkler system piping as a grounding electrode is prohibited by NFPA 13; however, NFPA 70 requires interior metal piping to be bonded in some situations. It’s all readily available — from Schedule 10 to our proprietary solutions, with a range of coatings and end finishes to choose from, including threading, swaging and grooving. Date: 08-08-2016. Chapter 9, Continued. RE: Sprinkler piping marking requirements. Depend on Wheatland for the industry’s broadest offering of fire sprinkler pipe. 610-559-3300; Get Directions; View All Locations Makes me chuckle, though, remembering something grammar school kids used to do. For Services within -21 Degrees F to – 60 Degrees F ( Saturated pressure < 3 PSIG): LLTRL, LLRTS, LLTS, LLTL. 6.3.7* Nonmetallic Pipe. 913.2.1 – NFPA 13 and NFPA 13R . PIPE MARKER SIZE CHART Letter and Label Dimensions in accordance with diameter Outside Pipe Diameter Including Covering Minimum Length of Label Field Color Minimum Height of Letters NOTE: It is recommended that pipes less than .75" in diameter be labeled with a permanent tag. For non-product-specific bulletins and technical information, please refer to Viking Sprinklers - Special Bulletins. RE: Fire protection pipe marking requirement. In the US, the NFPA does not set a requirement for the color of sprinkler water lines. It is a common practice to paint large feed lines red but once they are in the ceiling of your building you don't have to paint them a certain color. However, it is required that they be labled. The Wheatland Pipe app enables professionals involved in the mechanical and fire protection industries to view Wheatland’s full line of steel pipe products from their iPad device, including specifications, code information, and helpful videos and technical briefings on industry-related topics. The markings on sprinkler will have following details. Nonmetallic pipe in accordance with Table 6.3.1.1 shall be investigated for suitability in automatic sprinkler 6.6.4* Identification of Valves. Choose from our selection of fire sprinkler fittings, including over 150 products in a wide range of styles and sizes. Existing buildings must comply by 6/2/10. Fire sprinklers are essentially a valve that is activated by heat. Choose a product category below or use the search box above to find a specific product. ... hydrant flow tests enable municipalities to color-code their fire hydrants according to their strength of output. The employer may attach hose connections for fire fighting use to wet pipe sprinkler systems provided that the water supply satisfies the combined design demand for sprinklers and standpipes. The ASME Standard for Pipe Identification is a widely used guideline in determining pipe identification requirements. [such that each [floor] is a separate sprinkler control zone.] Construction equipment Handrails, Guardrails. Let's go. Coatings: Adjustable heavy epoxy coating system. Additional Fire Safety Requirements For Super High-rise Residential Building. History. 1910.159(c)(6) Protection of piping. 1.1.11. Pipe marking standards are not specifically outlined or defined by OSHA, but standard number 1910.261 (a) (3) (ii) notes the ASME's (ANSI) standard A13.1 as the recommended scheme for identification of pipe systems. It covers application, installation, location, performance, inspection, testing, and maintenance of fire alarm systems. fire safety engineer has the meaning that it has under the Environmental Planning and Assessment Regulation 2000 . 6.6.4.2 The identification sign shall be secured with corrosion-resistant wire, chain, or other approved means. Corporate Headquarters. Competitively priced. Pipe Color Codes Ansi Asme A13 1 Creative Safety Supply; Fire Sprinkler Pipe And … SERVICE Pressure Line (Pump Stations) SCHEDULES Safety Blue. Three-year update cycle. fire protective covering has the meaning that it has in the Building Code of Australia . • CPVC fire sprinkler pipe & fittings are rated for continuous service of 175 psi @ 150°F (1210 kPa @ 65°C) • Pressure rating is the same for ¾” through 3” at a ... material designation code for example, CPVC 4120-06. Uncovering closed valves, heavy pipe-wall deposits, or other problems in a water distribution system. The people in the safety department tell me I need to paint all of my sprinkler pipe red, whether it is in a warehouse or a residential building. Stay up to code. The ASME Standard for Pipe Identification is a widely used guideline in determining pipe identification requirements. ... under the nfpa commonly used color coding system. This form shall be completed by either a licensed master plumber, licensed master fire suppression piping … Designates radiation hazards. Under the NFPA's commonly used color coding system, which color is used for a hydrant that provides 1500 gallons per minute or greater? CERTIFICATION OF COMPLIANCE WITH COLOR CODING OF STANDPIPE/SPRINKLER PIPING AND VALVE HANDLES IN NEW & EXISTING BUILDINGS PURSUANT TO SECTIONS BC 903 AND 905 (LOCAL LAW 58/09) OF THE NEW YORK CITY BUILDING CODE Must be typewritten. 0 Non-Pressurized Refrigerating Piping and Related Process Piping. We provide prompt shipment from production facilities across the U.S. CRR of 1.0 and greater. The law does, however outline specific exceptions, such as branch piping Standpipe Valve Handles Dedicated standpipe valve handles must be painted red Combination standpipe valve handles must be painted yellow Owners of buildings with exposed sprinkler piping and standpipes must comply and hire one of four types of con-tractors to certify the color coding: • Licensed master plumbers; • Licensed master fire suppression piping contractors; • Registered design professionals; or BANDS. Where provided, fire pump rooms and automatic sprinkler system riser rooms shall be designed with adequate space for all equipment necessary for the installation, as defined by the manufacturer, with sufficient working space around the stationary equipment. The following standard defines recommended colors for industrial piping systems: ASME(ANSI) A13.1-1996 Standard Bright red paint with white lettering is recommended ofr fire protection piping: Several companies produce paint/lettering to meet this ASME requirement For whatever reason in my own life I’ve only ever looked at, examined, or noticed red-liquid sprinkler heads, and so I was completely unaware of the color coding system, which as Big Clive points out is more for easy identification than operation – the temperature breaking point is actually regulated by the bubble in the bulb! coded. BANDS. Waste containers These color codes help emergency responders know about potential health, fire, and chemical instability issues. Material Handling Equipment Piping systems containing dangerous materials. Standard: EN10216-1, P235TR1 / P235TR2. This reflects NFPA 291, which specifies the following: Where permitted by the New York City Fire Code, the Fire Department may approve the installation of alternative automatic fire-extinguishing systems complying with this code and the New York City Fire Code in lieu of automatic sprinkler protection. Identifying colors used for fluid piping systems. Fire Pump Rooms Sprinklers permit 1-hour fire barrier and horizontal assemblies for fire pump rooms. I don't need to mark the pipes based on occupancy or by zone. Fire pipe technical parameters. Series: 3 - DISCIPLINE-SPECIFIC CRITERIA. Duffy, P.E. The most commonly used steel pipe for sprinkler systems is black steel pipe. a manual fire alarm box is assigned a code that sounds from an audible. Hydrant Color Some jurisdictions paint hydrants or hydrant bonnets to identify the capacity of the hydrant. Caution, physical hazard. Steel is considered strong, durable and resistant to fire. Three-year update cycle. General surface color: Red. Completely revised to support the reorganized Standard, the essential Automatic Sprinkler Systems Handbook helps you implement the 2019 edition of NFPA 13 smoothly and efficiently.. All pipe endures NDT weld testing. Just make sure you don't paint the heads, otherwise it will affect the trigger times for the heads. The fire sprinkler system must also be part of a multipurpose system. Section 1.2. Fire Sprinkler Guide to Fire Sprinklers in the International Buildin… Plastic systems are specially listed for use in wet fire sprinkler systems. 0. • NFPA 72: National Fire Alarm and Signaling Code is the key document for fire alarm and fire sprinkler monitoring providers. Clearances around equipment to elements of permanent construction, including other installed equipment and … I don't need to mark the pipes based on occupancy or by zone. 1.1.12. ULC/ORD - C199 - Combustible Piping for Sprinkler Systems (1) Wet pillar hydrant (with yellow band in accordance with SS 575) (2) Dry pillar hydrant (whole hydrant in yellow) d. Wet/dry rising mains (1) Fire pump & control panel (2) Breeching inlet (excluding breeching inlet cabinet/enclosure) (3) Dry riser breeching inlet in yellow (4) Wet riser breeching inlet in red (5) Rising mains pipe is defined as the pressure exerted on a water supply system. Pipe markers that meet ANSI/ASME pipe labeling requirements . Whenever labeling pipes it is important to put all necessary information on the label. 20.3.5.4.3. Sprinkler Pipe Products. About Custom Pipe Markers. Download the app. Industry-leading hydraulic characteristics. 1.1.13. It also mandates that "dedicated" standpipe valve handles be painted red dedicated sprinkler valve handles green, and … Why are Fire Sprinkler Heads color coded? An automatic fire sprinkler is basically a valve activated by heat. It´s main component is a small glass bulb which holds a heat-sensitive liquid. They are color coded and each color represents the temperature at which it will explode, releasing the water flow. Water Supply Requirements For Wet Riser System. Shop Seton for top quality safety signs, labels, pipe markers, and more! Temperature Color Code. Pressure Relief Vent will be Grey, Water piping will be Green, Fire Sprinkler will be Red to Section 28-101.4.2 of the Administrative Code , shall be painted red and the handles of valves serving dedicated sprinklers shall be painted green ... NYC Building Code 2022 > 9 Fire Protection Systems > 903 Automatic Sprinkler Systems > 903.6 Painting of Dedicated Sprinkler Piping and Valve Handles 903.6.2 Fire Protection Systems, Alterations You can also use our Sprinkler Selector to quickly identify the right products for your project. Local Law 58/09 mandates that all exposed standpipes and sprinkler piping must be painted red (with some exceptions we'll get into). The people in the safety department tell me I need to paint all of my sprinkler pipe red, whether it is in a warehouse or a residential building. Nfpa Color Codes For Piping. Size range: DN15 to DN1200. Color Coding Local Law 58/09, effective 3/2/10. Dimension: EN10216-1. SERVICE Suction Line (Pump Stations) SCHEDULES Mid Blue. the markings shall be visible on every piece of pipe over 2ft (610mm) long." Often used in combination with yellow on tags, labels, signs, and floor markers. Fire sprinkler zones are not limited to fire alarm zones. plastcc (Civil/Environmental) (OP) 20 May 04 15:14. Test is conducted by placing the flame under the joint and fitting. The NFPA 704 diamond sign used to display this information has four colored sections: blue, red, yellow, and white. We recommend you paint the sprinkler piping red. G. Zone the wet-pipe sprinkler system [as shown on the Drawings.] Local Law 58/09 Color Coding, Effective 3/2/2010 A new local law 58/09 concerning the painting of sprinkler and standpipe has been made effective as of 3/2/2010 and is retroactive. You can see this ratings on frame or deflector in beside image. Application: Fire main pipe, fire pump pipe, fire standpipe, fire sprinkler branch pipe. 4.08 Design Criteria for Installation of Underground Piping for Fire Sprinkler Service Reference: 2007 C.B.C. ... are similar to dry pipe sprinkler systems in that they used closed. QRFS Team. * Note: Dedicated Sprinkler Valve handles must be painted Green; all painting must be complete before the hydrostatic test. Low Pressure, Low-Low Temperature Liquid and Vapor Piping. California is a state in the Western United States.California borders Oregon to the north, Nevada and Arizona to the east, the Mexican state of Baja California to the south; and has a coastline along the Pacific Ocean to the west. Pressure ratings exceeding 300 psi. Temperature Color Code; Blue: Green: Red: Yellow: White: Purple: ID. In buildings protected by fire sprinklers, over 99% of fires were controlled by fire sprinklers alone. Corroded Heads – IE head is greenish in color.-NFPA 25 Code 5.2.1.1.2 Loaded Heads – Sprinkler head should be ... –NFPA 25 Code 13.3.1 Fire Dept. NFPA 13D covers sprinkler systems that operate with standard water pressure, without a connection for the fire department. 0 Toggle navigation Home 0. WELCOME TO THE AUTOMATIC SPRINKLER ‘SUMMIT’ PRESENTED BY THE SAN FRANCISCO FIRE DEPARTMENT. Red and yellow barrels have specific meanings. 6.6.4.1 All control, drain, venting, and test connection valves shall be provided with permanently marked weather-proof metal or rigid plastic identification signs. for pressures up to 175 psig and in the Extra Strong Weight in sizes up to 8 in. Copper tubing is another piping material listed for sprinklers in NFPA 13. Upright Sprinklers must be installed in accordance with this section. The law outlines specific exceptions, such as branch piping (Stringer lines). Get in touch with us... 1-800-289-3473; Contact Sales Support Form; GIVE US FEEDBACK. Backsiphonage or backpressure (Fire sprinkler systems) ASSE 1047: Spill-resistant vacuum breaker assembly: High or low hazard: Backsiphonage only Sizes 1 / 4 ″–2″ ASSE 1056; CSA B64.1.3: Backflow preventer plumbing devices: Antisiphon-type fill valves for gravity water closet flush tanks: High hazard: Backsiphonage only: ASSE 1002, CSA B125.3 Also, plastic pipe (namely, CPVC and PEX tubing) is permitted for certain types of sprinkler systems. fire resistance level (FRL) has the meaning that it has in the Building Code of Australia . Certified to ASTM A135 and A795 Type E, Grade A. Complies with NFPA-13, 13R and 14. 0. NFPA 99C 2002 Edition. Pendent type. NB, Canada. It’s all American made and readily available. ; Hazardous Areas - European Classification Standard - European hazardous area classification with zones, protection … Steel Pipe. Visit our Pipe Markers Buying Guide, or use our Pipe Marker Finder … Trade sizes: 1−8. Schedule 40 pipe is available in hot-dip or galvanized black, and is easily painted without special preparation. F. If used the building fire pump(s) and combination standpipes shall serve the wet-pipe sprinkler system. Home / Uncategorized / types of fire sprinkler color code. Another adjustable rotary nozzle of the famous irrigation tool manufacturing Rainbird brand. Pipe Color Codes ANSI/ASME A13.1 The ANSI/ASME A13.1 pipe marking color code explained. Editor’s Note: “Back to Basics” is a column that will run periodically in PM Engineer reviewing the basic principles of … Title: NFPA 13-Installation of Sprinkler Systems Author: CCSF-DBI Last modified by: CCSF-DBI ... continued: Chapter 8, continued: Chapter 9 (1999 Chpt.6): Hangers, Bracing , and Restraint of System Piping Chapter 9, continued. • Pressure rating in pounds-force per square inch for water at both 73°F [23°C] and 180°F [82°C], shown Pipe End: Grooved end, Threaded end, Beveled end. — Terms 1.2.1.1. An exterior sidewall sprinkler (piping exposed). Fire sprinklers are extensively used worldwide, with over 40 million sprinkler heads fitted each year. Piping should be labeled by means of stenciling or adhesive markers that identify the system. We MAKE IT eZ. Fire alarm boxes Fire exit signs. The primary fire code writing organization is the private National Fire Protection Association or NFPA. [No sprinkler zone shall serve more than one [floor] [smoke compartment].] –NFPA 25 Code 13.7.1 ... Damaged piping – IE bent or cracked pipe. Coating thickness: 250 um to 550 um. In a major update, NFPA 13 has been fully reorganized by structuring the technical content in the order you need to do your … NOTIFIER by Honeywell is the largest manufacturer of engineered fire alarm systems with over 400 distributors worldwide and regional support operations on every continent. According to the corresponding rules and standards, the fire pipeline need to be red painted, (or with red anti corrosion epoxy coating), the point is to separately with other pipeline system. Since the fire sprinkler pipe usually installed in a static position, it requires a high level and restrict quality control. Sprinkler Pipe Painting is a service RSP offers to clients in all 50 states. Connection Caps – FDC should also be easily accessible. Plastic pipe fire sprinkler systems are available in CPVC and PEX from several manufacturers and are designed to be installed in certain residential and/or light hazard applications. Working temperature: -30℃ to 80℃ (Up top 760) General working pressure: 0.1 Mpa to 0.25 Mpa. Branch piping does not require color-coded painting. OSHA safety red. Viking Fire Sprinklers. Reduced Water Storage Requirements For Sprinkler Systems in Buildings (for Ordinary Hazard Groups) 1.1.14. The company tries its best to release products that will provide more facilities at a lower price. If you have a larger lawn size and are looking for a long sprinkler head, then ‘Adjustable Rotor Rainbird 22SA-RVAN Mini Rotary Pop-Up Sprays’ should be your choice. Steel pipe has long been the mainstay of piping materials for sprinkler piping systems. All buildings must comply. SAFETY PURPLE. High quality EN10242 Cold Threaded Fire Sprinkler Fittings Couplings 300PSI from China, China's leading EN10242 Fire Sprinkler Fittings Couplings product, with strict quality control Fire Sprinkler Fittings Couplings 300PSI factories, producing high quality EN10242 fire sprinkler threaded fittings products. FIRE QUENCHING Water and other substances used in sprinkler fire-fighting piping systems White on Red OTHER WATER White on Green Any other water, except for water used in sprinkler and fire-fighting piping systems COMPRESSED AIR Any vapor or gas under pressure that does not fit a category above DEFINED BY USER DEFINED BY USER DEFINED BY USER Oh, the humanity! light blue. For existing buildings, sprinkler work should comply with the 2014 Administrative Code, section 28-101.4.3 and the remainder of the Construction Codes, but in particular Building Code (BC) Chapter 9.Per the current 2014 Administrative Code, section 28-101.4.3, additions, alterations or modifications to sprinkler … SYSTEM 4000 COLOR 4063 Robotic Blue. Design Professional Requirements: Sprinkler Applicability of Code. Fire sprinkler heads feature heat-sensitive parts – either a glass bulb or a fusible link – that cause them to activate at a specific temperature. The NFPA color codes are part of the NFPA 704 standard for the identification of hazardous materials. Pipe marking standards are not specifically outlined or defined by OSHA, but standard number 1910.261 (a) (3) (ii) notes the ASME's (ANSI) standard A13.1 as the recommended scheme for identification of pipe systems. ANSWER: In response to your question, we have reviewed NFPA 13, NFPA 13R, and NFPA 70, 1999 editions, as the applicable standards. Home / Uncategorized / types of fire sprinkler color code. Editors: David R. Hague, P.E., and Chad R.W. Reply. Pipe Color Code Chart - ANSI/ASME A13.1 Label Color Text Color Pipe Contents Red White Fire-quenching fluids Orange Black Toxic and corrosive fluids Yellow Black Flammable fluids Brown White Combustible fluids 4 more rows ... Specify the style, wording, size, color and if special symbols are required. 12" 32" 203 mm 203 mm 305 mm 610 mm 813 mm .5" .75" 1.25" 2.5' 3.5' 13 mm Properly designing fire sprinkler systems for commercial and residential structures. (2) "Fire protection sprinkler system contractor" means an individual or organization that offers to undertake, represents itself as being able to undertake, or undertakes the plan, sale, installation, maintenance, or servicing of: (A) a fire protection sprinkler system; or (B) any part of a fire protection sprinkler system. NFPA sets the standards for technical aspects of sprinklers installed in the USA. If you do not have typical pipe marker needs or do not see your ideal wording, it is easy to customize with Seton. #8. Lengths: 21′, 24′ and 25′. 1.1.10. #2. Pipe is in direct contact with fire plume at 700°- 900°F (370°- 483°C) for a total of 10 minutes. In stock and ready to ship. SYSTEM 4000 COLOR 4086 Safety Blue. CONTACT US toggle menu. Mark pipes quickly and easily with pipe markers designed to meet ANSI/ASME pipe labeling requirements.We offer a large assortment of ready-made and customizable self-adhesive, snap-around, roll-form, and high-performance markers, plus many more. Seems like they were just touching. — Non-Defined Terms 1) Words and phrases that are not included in the list of definitions in Article 1.2.1.2. shall have the meanings which are commonly assigned to them in the context in which they are used in this Code, taking into account the specialized use of terms by the various trades and professions to which the terminology … A fire sprinkler is the component of a fire sprinkler system that discharges water when the effects of a fire have been detected, such as when a predetermined temperature has been exceeded. Pipe marking and labeling ansi asme a13 1 pipe labeling your guide to proper pipe marking osha vs ansi pipe marking what you. Wheatland Tube manufactures the industry’s most complete line of steel fire sprinkler pipe. Fire Safety Requirements For Petroleum Service Station. All buildings, no matter the size or occupancy, must have all exposed standpipes and sprinkler piping painted red. — Definitions 1.2.1. Exposed standpipes and sprinkler risers must be painted red; this color-coding must be certified ( BC 903.6). While caps (or bonnets) may be painted a different color to indicate their flow rate (which will be outlined in the next section), many hydrant barrels are painted a single, uniform color. All exposed Standpipe and Sprinkler piping must be painted RED. Pipe labels should show the name of the gas/vacuum system or the chemical symbol. … Pipe Color Codes Ansi Asme A13 1 Creative Safety Supply; Fire Sprinkler Pipe And … Brass pipe specified in Table 6.3.1.1 is permitted in the Standard Weight in sizes up to 6 in. Change / Revision Date: 05-06-2021. • Used in wet pipe residential sprinkler systems for one-and two-family dwellings and mobile homes per NFPA 13D • Used in wet pipe sprinkler systems for residential occupancies up to and including four stories in height per NFPA 13R K Factor K=3.0 (43,2) Thread Size 1/2” (15 mm) Bulb Type 3 mm Finish White, Chrome, Brass Tech Data TFP402 Related Topics . Canadian fire tech here. US Department of Defense Fire Code UFC 3-600- 01 (March 2018) 9-7.6.1.1 – Galvanized piping is only permitted for deluge sprinkler systems, valve trim, and drain piping exposed to the Facility exterior. ... Standard response or quick response fire sprinklers depend on fire code and fire-safety priorities ... the system is 1 inch orange fire pipe. A _____ manual fire alarm box is assigned a code that sounds from an audible notification device when a mechanically or electrically driven motor turns a wheel. The law states: “All exposed standpipes and sprinkler piping must be painted red.” There are exceptions, such as branch piping. Call our experts today at (877) 367-7732. June 29, 2019 colorpaints Leave a comment. RE: Sprinkler piping marking requirements. call 1-800-538-6723 for a frr estimate or to schedule your upcoming projects. SYSTEM 4000 COLOR 4081 Safety Red. Connection types: Threaded, Grooved, Flanged. Means of Egress Sizing Sprinklers lower egress capacity factor to 0.2 inches per occupant. plastcc (Civil/Environmental) (OP) 20 May 04 15:14. Color Mixing Theory - Subtractive and additive color mixing. UL 1887 - Standard for Safety Fire Test of Plastic Sprinkler Pipe for Visible Flame and Smoke Characteristics. Hydrant barrels are red or yellow. Sprinkler piping. PEX pipe is approved for use in fire sprinkler systems, under the National Fire Protection Association (NFPA) 13D code and UL 1821. Location. All buildings-no matter size or occupancy-must comply with these requirements. Seton offers more than 222,000 safety products designed to increase workplace safety and compliance. NFPA 13 (2007 edition) 6.3.8.2 "All pipe, including specially listed pipe allowed by 6.3.6, shall be marked along its length by the manufacturer in such a way as to properly identify the type of pipe. SAFETY YELLOW. With a melting point of about 2,700°F, steel pipe can withstand the heat within a burning building. Every fire sprinkler with glass bulb or with fusible metal link, they are all engraved with codes related to temperature ratings and with different colors. for pressures up to 300 psig. Codes & Standards; Tools; Industry Organizations; Home Department of Defense Unified Facilities Criteria (UFC) ... UFC 3-600-01 Fire Protection Engineering for Facilities, with Change 6 . 20.3.5.4.2.